Guided workflow

Review Combined TGA and DSC Events

Review simultaneous or aligned TGA–DSC signals together so thermal events can be compared with mass changes over the same temperature region. The workflow helps establish temporal or temperature coincidence while keeping chemical interpretation separate from the measured evidence.

  • NotyPlot
  • TGA DSC
  • 6 steps

Method NotyPlot

Start with Combined TGA-DSC data with identifiable temperature, mass and heat-flow signals.

  1. Import both signals
  2. Verify channel alignment
  3. Analyze thermal events
  4. Compare event ranges
  5. Review the interpretation
  6. Report aligned evidence

Result A joint review of thermal events and mass-loss behavior.

Figure 1. The workflow at a glance: what you start with, the steps, and what you leave with.

Before you start

  • Combined or alignable TGA and DSC data with a common temperature or time basis.
  • Correct mass and heat-flow channel mapping and units.
  • Known heat-flow sign convention, atmosphere and heating program.

Your workflow

Step-by-step workflow

  1. Import both signals

    Import the combined data and map the temperature, mass and heat-flow channels correctly.

  2. Verify channel alignment

    Confirm that the TGA and DSC channels share the intended temperature/time alignment.

  3. Analyze thermal events

    Run thermal analysis to review TGA mass-loss steps and DSC thermal events.

  4. Compare event ranges

    Compare event ranges, DTG peaks, DSC onset/peak/endset positions and residual mass behavior.

  5. Review the interpretation

    Separate observations of coincidence from proposed chemical mechanisms.

  6. Report aligned evidence

    Report the aligned evidence with the heating program, atmosphere and signal conventions.

Final quality check

  • TGA and DSC channels are actually aligned before event temperatures are compared.
  • Mass-loss steps and DSC events are reported as measured relationships rather than automatic causal assignments.
  • Heat-flow direction is interpreted correctly.
  • Overlapping events and shoulders are acknowledged.
  • Use the same temperature calibration or alignment basis for both channels.
  • Report the simultaneous-analysis test conditions.
  • Support reaction assignments with chemistry, evolved-gas analysis or other evidence when necessary.

Scientific notes

  • Coincident thermal and mass changes do not by themselves identify the reaction mechanism.
  • Different channel response times or misalignment can make events appear shifted.
  • Complex overlapping processes may not separate cleanly into one DSC event and one TGA step.

Common questions

What can combined TGA–DSC show?

It can show whether heat-flow events and mass changes occur in the same temperature region, which helps narrow interpretation.

Does an endotherm with mass loss prove evaporation?

No. It is consistent with several possibilities. Use sample chemistry and other evidence before assigning a mechanism.

Why do TGA and DSC event temperatures differ slightly?

Real kinetic differences, signal response and channel alignment can all contribute. Verify the shared temperature basis before interpreting the offset.

Start this workflow

Prepare your input and follow the guided steps in NotyPlot.