Detect candidate diffraction peaks and turn them into a reviewable XRD peak table before moving to fitting, crystallite-size calculations or phase comparison. The workflow keeps peak detection tied to the plotted pattern so weak or overlapping features can be checked visually.
- NotyPlot
- XRD
- 6 steps
Start with An XRD intensity-versus-angle dataset.
- Import the XRD pattern
- Review the background
- Set detection sensitivity
- Detect and inspect peaks
- Reject noise candidates
- Keep the reviewed peak table
Result A diffraction peak table and annotated pattern.
Figure 1. The workflow at a glance: what you start with, the steps, and what you leave with.
Before you start
- An XRD intensity-versus-angle dataset with the correct X-axis mapping.
- A pattern whose background and noise level have been inspected.
- Enough sampling across peaks for their positions to be meaningfully resolved.
Your workflow
Step-by-step workflow
Import the XRD pattern
Import the XRD pattern and confirm the diffraction-angle and intensity columns.
Review the background
Inspect the raw pattern and apply background correction only when needed and justified.
Set detection sensitivity
Choose a peak-detection sensitivity appropriate to the noise and feature strength.
Detect and inspect peaks
Run peak detection and compare every important candidate with the plotted signal.
Reject noise candidates
Remove or ignore candidates that are clearly noise artifacts and note overlapping regions that need fitting.
Keep the reviewed peak table
Keep the reviewed peak table or continue to XRD peak fitting for FWHM and downstream calculations.
Final quality check
- Strong expected features are detected without an excessive number of noise peaks.
- Weak candidates are visible in the original or appropriately processed pattern.
- Closely spaced features are not automatically assumed to be single peaks.
- Peak positions use the correct diffraction-angle unit.
- Document baseline correction or smoothing if it materially changes detection.
- Treat the peak list as detected features, not as phase identifications.
- Use fitting when FWHM or overlapping-peak separation is required.
Scientific notes
- Detection sensitivity trades missed weak peaks against false positives from noise.
- Peak detection alone does not provide a defensible FWHM for overlapping or asymmetric peaks.
- A detected peak position does not identify a crystalline phase by itself.
Common questions
Why are too many XRD peaks detected?
Noise, background structure or a high sensitivity setting can create extra candidates. Review the raw curve and lower sensitivity or correct the baseline when scientifically justified.
Can I use detected peaks directly for Scherrer analysis?
Scherrer calculations require suitable peak-width information. Fit appropriate peaks and review broadening before using them for crystallite-size estimates.
Does NotyPlot automatically identify phases from the peak table?
No. Peak detection and phase identification are separate tasks.
Related resources
- Workflow Analyze TGA Mass Loss and DTG Analyze thermogravimetric mass-loss steps together with the derivative thermogravimetry (DTG) curve. NotyPlot uses the derivative to help resolve loss events and reports step ranges, DTG peak temperatures and residual mass for review.
- Workflow Automatic XRD Peak Analysis in NotyPlot Run a guided automatic XRD peak-analysis pass, then review the detected and fitted results rather than treating automation as a final interpretation. The workflow is designed to shorten setup while keeping peak selection, fitting and scientific checks visible.
- Workflow Calculate Crystallite Size and Microstrain with Williamson-Hall Separate size-related and strain-related contributions to XRD peak broadening with a Williamson–Hall analysis built from several reviewed fitted peaks. The workflow emphasizes peak eligibility and the transformed linear fit because a numerical intercept and slope are only useful when the selected peaks support the model.
- Workflow Calculate Crystallite Size from XRD Using the Scherrer Equation Estimate coherent crystallite size from suitable fitted XRD peak widths using the Scherrer equation. The workflow keeps wavelength, shape factor, fitted FWHM and instrumental broadening visible because each directly affects the reported size.
Start this workflow
Prepare your input and follow the guided steps in NotyPlot.