Guided workflow
Summarize Repeated Measurements
Summarize repeated measurements with descriptive statistics while keeping sample size, spread and uncertainty visible. NotyPlot calculates values such as mean, median, standard deviation, coefficient of variation, range and a 95% confidence interval for the selected dataset.
- NotyPlot
- MEASUREMENT SUMMARY
- 6 steps
Start with A table of repeated measurements with consistent units.
- Import the measurement table
- Check units and missing values
- Calculate summary statistics
- Review the confidence interval
- Investigate unusual values
- Export and document sampling
Result Descriptive statistics and confidence intervals for the selected values.
Figure 1. The workflow at a glance: what you start with, the steps, and what you leave with.
Before you start
- A table of comparable numeric measurements using a consistent unit.
- A clear definition of what each repeated value represents.
- Sampling information needed to decide whether the values are independent and representative.
Your workflow
Step-by-step workflow
Import the measurement table
Import the measurement table and select the dataset or value series to summarize.
Check units and missing values
Verify units, remove non-numeric placeholders and identify missing values before interpreting statistics.
Calculate summary statistics
Run statistics and review n, mean, median, standard deviation, coefficient of variation, minimum and maximum.
Review the confidence interval
Inspect the 95% confidence interval when available and compare it with the observed spread.
Investigate unusual values
Investigate unexpected outliers against the source measurements rather than deleting them automatically.
Export and document sampling
Export the statistics CSV and report the sampling method together with the summary values.
Final quality check
- All summarized values have the same meaning and unit.
- Sample size is large enough for the intended inference.
- Mean and median differences are considered when the distribution is skewed.
- The confidence interval is not confused with the full data range or individual measurement uncertainty.
- Report n with mean and spread.
- Distinguish technical repeats, fields of view and independent specimens in the sampling description.
- Use a statistical comparison test separately when the question is whether groups differ significantly.
Scientific notes
- Descriptive statistics do not correct biased sampling or inconsistent measurement rules.
- A 95% confidence interval for the mean is not the same as a 95% prediction interval for individual measurements.
- Small samples can give unstable estimates of spread and confidence intervals.
Common questions
What statistics does the workflow provide?
The statistics view includes n, mean, median, standard deviation, CV%, minimum, maximum and a 95% confidence interval when available.
Should I remove outliers before calculating the mean?
Only with a defensible rule and source-data review. Do not remove a value simply because it changes the result.
Does a confidence interval show measurement error?
Not by itself. It summarizes uncertainty in the estimated mean under statistical assumptions; instrument and measurement uncertainty are separate concepts.
Related resources
- Workflow Analyze TGA Mass Loss and DTG Analyze thermogravimetric mass-loss steps together with the derivative thermogravimetry (DTG) curve. NotyPlot uses the derivative to help resolve loss events and reports step ranges, DTG peak temperatures and residual mass for review.
- Workflow Automatic XRD Peak Analysis in NotyPlot Run a guided automatic XRD peak-analysis pass, then review the detected and fitted results rather than treating automation as a final interpretation. The workflow is designed to shorten setup while keeping peak selection, fitting and scientific checks visible.
- Workflow Calculate Crystallite Size and Microstrain with Williamson-Hall Separate size-related and strain-related contributions to XRD peak broadening with a Williamson–Hall analysis built from several reviewed fitted peaks. The workflow emphasizes peak eligibility and the transformed linear fit because a numerical intercept and slope are only useful when the selected peaks support the model.
- Workflow Calculate Crystallite Size from XRD Using the Scherrer Equation Estimate coherent crystallite size from suitable fitted XRD peak widths using the Scherrer equation. The workflow keeps wavelength, shape factor, fitted FWHM and instrumental broadening visible because each directly affects the reported size.
Start this workflow
Prepare your input and follow the guided steps in NotyPlot.
