Guided workflow
Compare Phase Area Fractions
Summarize repeated image-based phase area fractions after segmentation has already been reviewed. The workflow is intended for comparing comparable percentage measurements across images or samples, not for deciding where phase boundaries should be drawn.
- NotyPlot
- PHASE PERCENTAGE
- 6 steps
Start with Phase-percentage measurements with sample or image labels.
- Import phase percentages
- Verify the measurement basis
- Calculate phase statistics
- Review spread and uncertainty
- Check segmentation outliers
- Export and document sampling
Result Summary statistics for comparable phase-fraction values.
Figure 1. The workflow at a glance: what you start with, the steps, and what you leave with.
Before you start
- Phase-percentage values with sample, image or field labels.
- Consistent phase definitions and segmentation rules across the values being compared.
- A known percentage basis, typically area fraction from a defined ROI or image field.
Your workflow
Step-by-step workflow
Import phase percentages
Import the phase-percentage table and label the sample or field represented by each dataset.
Verify the measurement basis
Confirm that the same phase definition, ROI rule and percentage basis were used across measurements.
Calculate phase statistics
Run statistics for the selected phase-percentage series.
Review spread and uncertainty
Review n, mean, median, standard deviation, CV, range and confidence interval where available.
Check segmentation outliers
Check unusual values against the original segmentation and field selection.
Export and document sampling
Export the summary and report how images, ROIs and phase thresholds were selected.
Final quality check
- Percentages being combined represent the same phase and denominator.
- Fields of view are not selectively chosen only for a desired composition.
- Outlying values are checked against segmentation quality.
- Variation between fields is reported rather than hidden behind the mean.
- Describe how many images or fields were sampled.
- Keep segmentation rules consistent when comparing samples.
- Do not interpret area fraction as volume or mass fraction without the assumptions needed for that conversion.
Scientific notes
- Statistics cannot correct segmentation bias or nonrepresentative field selection.
- Image area fraction depends on thresholding, ROI and feature classification choices.
- A small number of fields may not represent a heterogeneous sample.
Common questions
Can I average phase percentages from different segmentation settings?
That is risky. Use consistent phase definitions and segmentation rules before combining values statistically.
Is image area fraction the same as volume fraction?
Not automatically. Stereological assumptions may be needed, depending on sample and sectioning.
What should I report with the mean phase fraction?
Include n, spread and how images, ROIs and thresholds were selected.
Related resources
- Workflow Analyze TGA Mass Loss and DTG Analyze thermogravimetric mass-loss steps together with the derivative thermogravimetry (DTG) curve. NotyPlot uses the derivative to help resolve loss events and reports step ranges, DTG peak temperatures and residual mass for review.
- Workflow Automatic XRD Peak Analysis in NotyPlot Run a guided automatic XRD peak-analysis pass, then review the detected and fitted results rather than treating automation as a final interpretation. The workflow is designed to shorten setup while keeping peak selection, fitting and scientific checks visible.
- Workflow Calculate Crystallite Size and Microstrain with Williamson-Hall Separate size-related and strain-related contributions to XRD peak broadening with a Williamson–Hall analysis built from several reviewed fitted peaks. The workflow emphasizes peak eligibility and the transformed linear fit because a numerical intercept and slope are only useful when the selected peaks support the model.
- Workflow Calculate Crystallite Size from XRD Using the Scherrer Equation Estimate coherent crystallite size from suitable fitted XRD peak widths using the Scherrer equation. The workflow keeps wavelength, shape factor, fitted FWHM and instrumental broadening visible because each directly affects the reported size.
Start this workflow
Prepare your input and follow the guided steps in NotyPlot.