Guided workflow

Estimate Optical Band Gap

Estimate an optical band gap from UV–Vis data with a Tauc plot while keeping the signal transformation, transition model and fitted linear region visible. NotyPlot supports absorbance, transmittance, absorption-coefficient and diffuse-reflectance inputs, with optional thickness where conversion requires it.

  • NotyPlot
  • UVVIS
  • 6 steps

Method NotyPlot

Start with UV-Vis data with the information needed for the selected Tauc representation.

  1. Import the optical spectrum
  2. Verify the signal conversion
  3. Choose the transition model
  4. Inspect the Tauc fit
  5. Refine the linear range
  6. Report the band gap and model

Result A reviewed Tauc plot and optical band-gap estimate.

Figure 1. The workflow at a glance: what you start with, the steps, and what you leave with.

Before you start

  • UV–Vis data with a known wavelength or photon-energy axis and known signal type.
  • Optical thickness when needed to convert absorbance or transmittance into an absorption coefficient.
  • A justified transition model: direct/indirect and allowed/forbidden as appropriate to the material.

Your workflow

Step-by-step workflow

  1. Import the optical spectrum

    Import the UV–Vis dataset and confirm the spectral axis, units and signal representation.

  2. Verify the signal conversion

    Select or verify the Tauc signal type; enter optical thickness when it is required for the chosen conversion.

  3. Choose the transition model

    Choose the transition model to define the Tauc exponent.

  4. Inspect the Tauc fit

    Run the band-gap analysis and inspect the transformed Tauc plot, automatic fit window and R².

  5. Refine the linear range

    Adjust the linear fit range when the automatic window includes curvature, noise or unrelated transitions.

  6. Report the band gap and model

    Report the extrapolated band gap together with signal transformation, transition assumption and fitted energy range.

Final quality check

  • The signal transformation is appropriate to the available UV–Vis measurement.
  • The selected region is reasonably linear rather than chosen only to maximize R².
  • The extrapolation to the energy axis is visually consistent with the fitted edge.
  • Changing the fit window does not cause an unexplained large shift in the result.
  • Record the transition model and fit range.
  • State how absorbance, transmittance or reflectance was converted for Tauc analysis.
  • Compare samples using the same justified method rather than changing the model to obtain a preferred value.

Scientific notes

  • Tauc analysis is model-dependent and can be ambiguous for disordered, indirect, multi-transition or strongly scattering materials.
  • Diffuse reflectance may require an appropriate transform and assumptions distinct from transmission measurements.
  • A high R² alone does not prove that the selected region represents the correct absorption edge.

Common questions

Which Tauc transition should I choose?

Choose the transition type supported by the material system and your analysis method. Do not select a model only because it gives a cleaner straight line.

Why does the band gap change when I move the fit window?

The estimate is an extrapolation from the selected linear region. Curvature, noise and multiple transitions make the result sensitive to that choice.

Can I use transmittance data directly?

Not blindly. The workflow can transform supported signal types, but the required assumptions and optional sample thickness should be checked and reported.

Start this workflow

Prepare your input and follow the guided steps in NotyPlot.