Documentation

NotyScale Right Panel: Complete Settings Reference

Understand every section of the NotyScale right panel: calibration, length, presets, Style, Text, Color, Layout and export controls.

How the right-hand panel is organized

The right-hand Scale Bar panel contains the image and calibration source, the bar creation or Length area, four inspector tabs and the Export Image action. Its contents depend on whether an image and an active scale bar exist. Start by confirming the source and calibration, then create a bar and work through Style, Text, Color and Layout. This reference describes the current editor controls in panel order. The screenshots show the text-label tab named Text. Older interface versions or help material may call it Label; both names refer to the text controls discussed here.

Panel header, collapse and width

Click the Scale Bar panel header to collapse or expand the settings. Use the resize handle at the panel boundary to adjust its width when you need more canvas space or wider controls. These actions change the workspace presentation. If the image source block is hidden while the bar is focused, leave that focused editing state to inspect the source again.

Image Setup: calibration status

The calibration row displays the active calibration name and its reference relationship, expressed as a pixel distance equal to a physical distance and unit. An Attached badge identifies a calibration associated with the image. A warning indicates that the image is not calibrated; pixel mode indicates that the bar is being expressed in pixels. Inspect this row before setting a scientific length. The physical meaning of a bar comes from calibration, so a readable label alone cannot establish accuracy.

Calibrate, Change and reset calibration

Use Calibrate or Change in the source row to open calibration selection. Select a calibration appropriate to the active image and verify the reference and unit. When an override is active, the reset control returns to the attached calibration when one exists, or to automatic selection otherwise. Recheck the bar after switching calibration because the same physical distance can correspond to a different number of pixels.

Original or prepared image

The image source row identifies the original or prepared working image and shows available pixel dimensions. Prepare opens Image Preparation; after preparation the row offers Edit and displays the prepared dimensions. Embedded contexts can present Crop instead. Use this entry to crop or clean the image, inspect the preview, and apply a valid result. Retain the source image and verify calibration and bar placement after preparation. The detailed Image Preparation article covers selection tools and undo behavior.

Add Scale Bar and the empty state

Before a bar exists, the panel presents Add Scale Bar. It is disabled until an image is loaded. Clicking it creates the bar and reveals the Length area and inspector tabs. If saved presets are available to a signed-in user, the empty state can also offer creation from a preset. If these options are absent, check the image state, account state and whether a bar already exists.

Length, physical unit and pixel equivalent

Length is the large numeric field above the inspector tabs. Enter the distance represented by the bar in the displayed unit. With a physical calibration, the panel also shows the equivalent pixel length. With pixel mode, the displayed unit is px. Suggested round values appear when multiple choices are available; selecting one sets the length in the current unit. These suggestions help choose a readable value but still require an appropriate calibration and scientific judgment.

Presets menu: apply, save and manage

The bookmark menu beside Length lists quick presets that can be applied directly. The current loaded preset name can appear under the Length area. Save opens the preset dialog and requires an active bar; Manage opens the preset management dialog. Preset controls are hidden in guest mode. In the save dialog, use a meaningful name and optional note and review anchor and orientation. Always verify the target image calibration after applying a saved appearance.

More menu: Reset Style and Remove

The More menu beside Length contains Reset Style and Remove. Reset Style restores the editor style settings through the reset action; inspect the bar afterward before exporting. Remove clears the active scale bar and returns the panel to the creation state. Use these deliberately when starting a new design or removing an overlay. Export requires an active bar, so removing it also removes the condition needed for the export action.

Style tab: Classic, Bar and Graded types

The type selector changes the scale bar design. Classic uses a simple line. Bar provides a background box around the bar. Graded, also called Ruler, exposes division and tick controls. Type-specific sections appear only when relevant: ruler ticks are shown for Graded, background-box controls for non-Classic types, and end marks for non-Graded types. A control disappearing after a type change can therefore be expected behavior.

NotyScale Style tab with Bar selected, line thickness, end marks, corner and padding controls
Bar is selected. Ruler divisions are not shown; Soft shadow and Outline are off.

Style tab: line thickness and end marks

Thickness changes the visible line width using a slider or numeric field. Use the slider for quick visual adjustment and the number input for a deliberate value. End marks add endpoint marks for the non-Graded designs; Graded uses its tick controls instead. Thickness affects readability and appearance and should be inspected at the final figure size. The bar distance is set in the Length area above the tabs.

Style tab: ruler divisions and tick side

For Graded, Divisions controls the major segmentation of the ruler. Tick side places the marks above the line, across both sides at the center, or below the line. Major tick length adjusts their extent using a ratio setting. These choices should preserve a clear distinction between intervals without crowding the image. Changing division count alters ruler detail; it does not provide evidence for a more accurate underlying calibration.

Style tab: minor ticks

Enable Minor ticks to reveal the number of minor ticks between divisions and their length ratio. Disable the switch for a simpler ruler with major divisions only. Keep minor ticks shorter or otherwise distinguishable from major ticks. When a figure will be reduced in size, inspect an exported sample and reduce the tick density if the marks merge or appear noisy.

Style tab: box radius, padding and linked corners

For non-Classic types, the box section controls the background geometry. Radius rounds its corners; horizontal and vertical padding add space around its contents in each direction. If individual corners were rounded separately on the canvas, the panel shows a control to link the corners again and restore one shared radius. Increase padding only as much as needed for readability, since a large background can cover scientific features. The background color and opacity are configured in Color.

Style tab: shadow and outline

Enable Shadow to reveal fade and padding controls. Fade controls the softness of the shadow, while padding controls its extent around the overlay. Shadow color and opacity are available in Color while Shadow is enabled. Enable Outline to reveal its width control; the outline surrounds the line and label to improve separation from the image. Its color is configured in Color while Outline is enabled. Use small, readable effects and check that they do not conceal fine structures.

Text tab: value label, font and size

Show label controls the single measurement label. Choose Font from the available family list, then adjust Size with its slider or numeric input. When the single label is visible, its size, position and gap controls are available. If Graded tick labels are active, the panel explains that state and offers Use single label. Single-value and ruler-division labels are alternate modes, so enabling one changes which label controls are relevant.

NotyScale Text tab with Show label enabled, Arial font, size, position and gap controls
The Text tab shows the single value label; ruler tick-label settings are not shown.

Text tab: label position and gap

Position places the single value above, below, left or right of the bar. Gap sets the separation between the label and the bar. Adjust them together so the text is visibly associated with its bar and does not overlap a specimen feature or image edge. A very large gap can make the measurement ambiguous. Check the exported label at the intended panel width, particularly when using a vertical bar.

Text tab: graded tick labels, direction and unit

For Graded, Tick labels enables labels on the ruler divisions and switches away from the single-value label. Its Size and Gap controls are separate from the single-label settings. Direction chooses horizontal or vertical division text. Show unit controls whether the physical unit is included in major labels. If units are hidden there, ensure the figure still communicates the scale unambiguously. Use single label to return to one overall measurement label.

Color tab: themes and custom colors

Theme chips apply a coordinated color appearance as a starting point. The Custom section provides separate line and text color pickers and displays their color values. The link button beside Text controls whether text follows the line color. When linked, the panel indicates that relationship; unlink to configure different text and line colors. Inspect contrast over the actual background after applying a theme or moving the bar.

NotyScale Color tab with White on black selected, linked white text and line, and black box at 70 percent opacity
White on black is selected. The screenshot shows box opacity, not enabled shadow or outline colors.

Color tab: background and opacity

Background controls appear for non-Classic types. Choose the box color in the picker and adjust opacity with the picker or the dedicated percentage slider and numeric field. Zero opacity makes the background transparent; increasing it makes the box more opaque. Pair these settings with padding and radius in Style to create a compact readable background without unnecessarily obscuring the specimen.

Color tab: outline and shadow color

An Outline color section appears only when Outline is enabled in Style. Choose a color that separates the line and text from the underlying image. A Shadow section similarly appears when Shadow is enabled; it includes shadow color and an opacity percentage. Configure shadow fade and padding back in Style. If a color section is missing, check its corresponding enable switch before looking for another control.

Layout tab: orientation

Choose Horizontal or Vertical to change the bar orientation. This is separate from the direction setting for graded tick label text in Text. After changing orientation, inspect the bar bounds, label position and nearby structures. The total physical distance is still controlled by Length above the tabs, and thickness is configured in Style.

Layout tab: placement grid and margin

The placement grid offers nine anchors: top, middle and bottom combined with left, center and right. Choose an anchor for consistent placement, then adjust Margin, displayed as a percentage, to change the edge spacing used by the placement controls. Dragging the bar on the canvas provides another positioning method. Inspect the full overlay including its text and background so that it remains inside the intended visible area.

NotyScale Layout tab showing horizontal orientation, bottom-left placement, 4 percent edge margin and X/Y coordinates
Layout controls orientation and placement; Length remains above the tabs.

Layout tab: exact X and Y position

The X and Y fields specify the bar position in image pixels. Use them when exact placement is easier than dragging or when matching a figure series. These coordinate units remain px even when Length is calibrated in a physical unit. Confirm the resulting position on the canvas after entry, especially when a large label or background extends beyond the line itself.

Export Image appears at the bottom when both an image and active scale bar are present. The footer summarizes the selected output format and DPI. Open the export dialog to review filename, format, output dimensions and DPI, then download or save to the library as available. Inspect the actual exported file at final figure size. Export settings do not repair an inaccurate calibration; check the source row and physical Length before producing the file.

NotyScale Export Image dialog with PNG selected, 1500 by 977 pixel output, 300 DPI and locked PSD PDF SVG formats
PNG is selected at original size and 300 DPI. PSD, PDF and SVG are locked for the account shown.

A complete panel review before publication

Review the source and calibration first. Confirm Length and unit, then inspect the chosen type, thickness, ruler ticks, box and effects in Style. Check the appropriate single or graded labels, colors and contrast, followed by orientation and exact placement. Finally open Export Image and examine the resulting file. If a setting is hidden, check the selected bar type, label mode and effect switches described in this reference.

Continue your work