Follow a workflow from raw data to result.

Step-by-step workflows for XRD, spectroscopy, thermal analysis, plotting and image measurement. Each one opens in the tool that does the work.

Try: XRD FTIR peaks TGA band gap scale bar

Showing 8 of 24 workflows

  • Step by step
  • Free plan
  • Runs in your browser

All workflows by technique

8 workflows

X-ray diffraction

From a raw pattern to peaks, fits, crystallite size and a figure ready for a paper.

  1. Automatic XRD Peak Analysis in NotyPlot Run a guided automatic XRD peak-analysis pass, then review the detected and fitted results rather than treating automation as a final interpretation. The workflow is designed to shorten setup while keeping peak selection, fitting and scientific checks visible. NotyPlot 6 steps
  2. Calculate Crystallite Size and Microstrain with Williamson-Hall Separate size-related and strain-related contributions to XRD peak broadening with a Williamson–Hall analysis built from several reviewed fitted peaks. The workflow emphasizes peak eligibility and the transformed linear fit because a numerical intercept and slope are only useful when the selected peaks support the model. NotyPlot 6 steps
  3. Calculate Crystallite Size from XRD Using the Scherrer Equation Estimate coherent crystallite size from suitable fitted XRD peak widths using the Scherrer equation. The workflow keeps wavelength, shape factor, fitted FWHM and instrumental broadening visible because each directly affects the reported size. NotyPlot 6 steps
  4. Compare Multiple XRD Patterns Compare multiple XRD patterns in one figure to inspect peak-position changes, relative profile shape and sample-to-sample differences. NotyPlot can overlay, stack or normalize diffraction patterns, but the display mode should match the scientific question. NotyPlot 6 steps
  5. Create a Publication-Ready XRD Plot Turn a checked diffraction pattern or XRD comparison into a publication-ready figure without confusing display styling with analysis. The workflow focuses on readable 2θ axes, sample labels, reviewed peak annotations and export quality. NotyPlot 6 steps
  6. Detect and Fit XRD Peaks and Measure FWHM Fit diffraction peaks to obtain reviewed peak positions and FWHM values rather than relying on a simple detected maximum. NotyPlot supports Gaussian, Lorentzian and pseudo-Voigt profile choices, including joint handling of overlapping fit windows. NotyPlot 6 steps
  7. Find XRD Peaks Detect candidate diffraction peaks and turn them into a reviewable XRD peak table before moving to fitting, crystallite-size calculations or phase comparison. The workflow keeps peak detection tied to the plotted pattern so weak or overlapping features can be checked visually. NotyPlot 6 steps
  8. Remove XRD Background Before Peak Analysis Subtract a slowly varying XRD background before peak analysis while preserving real diffraction features. NotyPlot provides baseline-processing options so the corrected curve can be compared with the original rather than accepted blindly. NotyPlot 6 steps

Ready to try it on your own data?

Open the workspace and follow any workflow step by step, or browse the tools behind them.